Resuscitation Unit with Fixed Baby Cradle (Standard) with 2 modes Skin / Manual mode This is mobile Neonatal Resuscitation Unit mounted on wheels with fixed baby cradle & lower shelf along with facility of Oxygenation, Suction and Intubation Mechanical Specification Heater Box Consists of Ceramic Infra Red Heater 650 Watts Metallic Heater Box. The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards Halogen Examination Lamp (12 Volts, 50 Watts) To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Clear acrylic collapsible side panels . Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy. Acrylic tray and cushion mattress with head up/down facility. Acrylic X-ray tray with X-ray guide for positioning the cassette. The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf S.S. IV Stand Oxygenation : Oxygen regulator with Hose pipe, Place to keep Cylinder, Chain to hold Oxygen Cylinder, Flow meter, Humidifier bottle, Silicone Patient Tubing, Manual Silicone Resuscitator 250ml with 00 & 01 size mask. Suction : Electrically operated low pressure Suction unit with 2 Autoclavable 500 ml suction jars, Regulator, Suction gauge and silicone tubing. Intubation : Laryngoscope with size 0 & 1 Straight Blades, Silicone Airways 000, 00 & 0
....Standard Fowler Knee Rest Bed
....Standard Fowler Bed Standard fowler bed with mechanically operated back rest and knee rest by crank mechanism. Size: 2030 � 900 � 530 mm. Epoxy coated mild steel frame work and 4 section top. Tubular head & foot bows made of stainless steel. Mounted on protective stumps. Provision for I.V. Rod. Freight saving knock-down construction
....Standard Fowler Steel Bed
....Standard Fowler Steel Tubes Bed
....Hot Water Bottles, Superior Quality (as per BS Standard)
....Infant Radiant Warmer (STANDARD) Technical Specification Microprocessor controlled unit allow three operational mode: Prewarm, Manual or Automatic(Servo Controlled temperature System). Audio and Visual alarm function for Power failure, temperature deviation, over temperature & Temperature sensor failure. APGAR timer to record therapy time Convenient X-ray cassette under infant bed Heater consists of anti-explosion micro crystal quartz infrared radiation tubes, radiation source 800W. Heater head can be adjusted ± 90º horizontally Inclination of infant bed is adjustable. Observe light angle is adjustable. Foldable transparent side panels Optional Parts 1. RS232 Connector 2. Drawer 3. Height Adjustable
....Resuscitation Unit (STANDARD) Technical Specification: Microprocessor controlled unit allow three operational mode, Pre-warm, Manual or Automatic(Servo Controlled temperature System). Audio and Visual alarm function for Power failure, temperature deviation, over temperature & Temperature sensor failure. APGAR timer to record therapy time Convenient X-ray cassette under infant mattress. Heater consists of anti-explosion micro crystal quartz infrared radiation tubes, radiation source 800W. Heater head can be adjusted ± 90º horizontally Inclination of infant bed is adjustable. Observe light angle is adjustable Foldable transparent side panels. A second thermal cut-out function for more safety. Skin temperature sensor failure protect function avoid over temperature Temperature deviation can be amended in front panel directly Low pressure suction unit, oxygen supply system and LED phototherapy unit Electric height adjusted suit for operation Optional Part: 1. RS232 connector 2. Drawer
....Standard Plain Hospital Bed at CIF prices from India, China Medical Lab Hospital Furniture Manufacturers
....Standard Plain Hospital Lab Bed, India
....Infant Incubators (STANDARD) Technical Specification Microprocessor based servo controlled temperature system Controlled mode: Air Air temperature control range : 25°C - 38°C (>37°C temperature setting.) Temperature and Heater output displayed by LED. Audio and Visual alarm function for Power failure, temperature deviation, over temperature, temperature sensor failure and fan failure. Inclination of infant bed is adjustable. With Phototherapy unit and tray. Humidity is continuously adjustable Double wall hood. 4 operating windows and 2 access ports. A second thermal cut-off function for more safety Standard Configuration: Main body including the transparent hood, control system, infant bed, water trough,IV pole, mattress, cabinets, Silence Castors With optional function Phototherapy up side unit Phototherapy down side unit RS232 Connector. Tray & Pole. Infant bed pulled from front and side door
....Diagnostic set (Pin Contacting Fitting) 2.5V standard illumination for use with 2 batteries type Otoscope Head: Pin contacting fitting, Chrome plated. Fixed lens 4x in plastic mount may be removed for introductions of instruments. Reusable specula: (2.5, 3.5 and 4.5mm) included. Deluxe Opthalmoscope head: Pin contact fitting. lens selection wheel permits choice of corrective lenses from 0 to -25 and 0 to +40 diopters single large circle aperture. Bent-arm illuminator: Tongue blade holder : Plastic nasal speculum: Chrome plated two laryngeal mirrors: Number 3 and 4 Battery Handle: Chrome plated. Rheostat for adjustment of illumination Require: 2x C size batteries, replacement bulb 2.5V Supply: Soft case or black plastic case
....Adult Diaper, Standard Type, Non Woven NET adult diaper (or adult nappy) is used by the adults suffering from incontinence, mobility impairment, severe diarrhea or dementia. People who are bedridden or in wheelchairs may also wear diapers as they are unable to access the toilet independently....
Disposable PVC Laryngeal Mask Airway - Standard 100% Medical Grade PVC. No aperture bars. A Stainless Steel spring is inserted in the tube to reduce the risk of kinking....