• HOME
  • ABOUT US
  • OUR PRODUCTS
  • Contact

Search

Search by Alphabet :

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Resuscitation Unit with Fixed Baby Cradle & Drawers (Standard) with 3 modes Skin /Air / Manual mode

Product Code: NMCBS26037 - (Resuscitation Unit with Fixed Baby Cradle & Drawers (Standard) with 3 modes Skin /Air / Manual mode)

Resuscitation Unit with Fixed Baby Cradle & Drawers (Standard) with 3 modes Skin /Air / Manual mode Technical Specification Heater Box Consists of Ceramic Infra Red Heater 650 Watts Metallic Heater Box. The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards Halogen Examination Lamp (12 Volts, 50 Watts) To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Clear acrylic collapsible side panels . Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy. Acrylic tray and cushion mattress with head up/down facility. Acrylic X-ray tray with X-ray guide for positioning the cassette. The design aspects also allow ease of dismantling baby care area during cleaning or fumigation. Essential Attachments Lower Shelf and 3 Drawer Storage Cabinet. S.S. IV Stand. Oxygenation : Oxygen regulator with Hose pipe, Place to keep Cylinder, Chain to hold Oxygen Cylinder, Flow meter, Humidifier bottle, Silicone Patient Tubing, Manual Silicone Resuscitator 250ml with 00 & 01 size mask. Suction : Electrically operated low pressure Suction unit with 2 Autoclavable 500 ml suction jars, Regulator, Suction gauge and silicone tubing. Intubation : Laryngoscope with size 0 & 1 Straight Blades, Silicone Airways 000, 00 & 0

....


   

Resuscitation Unit with Fixed Baby Cradle & Drawers (Standard) with 2 modes Skin / Manual mode

Product Code: NMCBS26038 - (Resuscitation Unit with Fixed Baby Cradle & Drawers (Standard) with 2 modes Skin / Manual mode)

Resuscitation Unit with Fixed Baby Cradle & Drawers (Standard) with 2 modes Skin / Manual mode Technical Specification Heater Box Consists of Ceramic Infra Red Heater 650 Watts Metallic Heater Box. The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards Halogen Examination Lamp (12 Volts, 50 Watts) To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Clear acrylic collapsible side panels . Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy. Acrylic tray and cushion mattress with head up/down facility. Acrylic X-ray tray with X-ray guide for positioning the cassette. The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf and 3 Drawer Storage Cabinet. S.S. IV Stand. Oxygenation : Oxygen regulator with Hose pipe, Place to keep Cylinder, Chain to hold Oxygen Cylinder, Flow meter, Humidifier bottle, Silicone Patient Tubing, Manual Silicone Resuscitator 250ml with 00 & 01 size mask. Suction : Electrically operated low pressure Suction unit with 2 Autoclavable 500 ml suction jars, Regulator, Suction gauge and silicone tubing. Intubation : Laryngoscope with size 0 & 1 Straight Blades, Silicone Airways 000, 00 & 0

....


   

Resuscitation Unit with Fixed Baby Cradle (Premium) with Microprocessor based temperature controller with 3 modes Skin /Air / Manual mode

Product Code: NMCBS26039 - (Resuscitation Unit with Fixed Baby Cradle (Premium) with Microprocessor based temperature controller with 3 modes Skin /Air / Manual mode)

Resuscitation Unit with Fixed Baby Cradle (Premium) with Microprocessor based temperature controller with 3 modes Skin /Air / Manual mode This is mobile Neonatal Resuscitation Unit mounted on wheels with fixed baby cradle & lower shelf along with facility of Oxygenation, Suction and Intubation Mechanical Specification Heater Box Consists of Ceramic Infra Red Heater 650 Watts The source box can be swivelled to take X-ray. Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run. The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards Halogen Examination Lamp (12 Volts, 50 Watts) To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Clear acrylic collapsible side panels . Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy. Acrylic tray and cushion mattress with head up/down facility. Acrylic X-ray tray with X-ray guide for positioning the cassette. The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf Side Mounted Monitor tray Pole for Syringe Pump / Infusion Pump S.S. IV Stand. Oxygenation : Oxygen regulator with Hose pipe, Place to keep Cylinder, Chain to hold Oxygen Cylinder, Flow meter, Humidifier bottle, Silicone Patient Tubing, Manual Silicone Resuscitator 250ml with 00 & 01 size mask. Suction : Electrically operated low pressure Suction unit with 2 Autoclavable 500 ml suction jars, Regulator, Suction gauge and silicone tubing. Intubation : Laryngoscope with size 0 & 1 Straight Blades, Silicone Airways 000, 00 & 0

....


   

Resuscitation Unit with Fixed Baby Cradle (Premium) with Microprocessor based temperature controller with 2 modes Skin / Manual mode

Product Code: NMCBS26040 - (Resuscitation Unit with Fixed Baby Cradle (Premium) with Microprocessor based temperature controller with 2 modes Skin / Manual mode)

Resuscitation Unit with Fixed Baby Cradle (Premium) with Microprocessor based temperature controller with 2 modes Skin / Manual mode This is mobile Neonatal Resuscitation Unit mounted on wheels with fixed baby cradle & lower shelf along with facility of Oxygenation, Suction and Intubation Mechanical Specification Heater Box Consists of Ceramic Infra Red Heater 650 Watts The source box can be swivelled to take X-ray. Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run. The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards Halogen Examination Lamp (12 Volts, 50 Watts) To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Clear acrylic collapsible side panels . Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy. Acrylic tray and cushion mattress with head up/down facility. Acrylic X-ray tray with X-ray guide for positioning the cassette. The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf Side Mounted Monitor tray Pole for Syringe Pump / Infusion Pump S.S. IV Stand. Oxygenation : Oxygen regulator with Hose pipe, Place to keep Cylinder, Chain to hold Oxygen Cylinder, Flow meter, Humidifier bottle, Silicone Patient Tubing, Manual Silicone Resuscitator 250ml with 00 & 01 size mask. Suction : Electrically operated low pressure Suction unit with 2 Autoclavable 500 ml suction jars, Regulator, Suction gauge and silicone tubing. Intubation : Laryngoscope with size 0 & 1 Straight Blades, Silicone Airways 000, 00 & 0

....


   

Resuscitation Unit with Fixed Baby Cradle (Standard) with 3 modes Skin / Air / Manual mode

Product Code: NMCBS26041 - (Resuscitation Unit with Fixed Baby Cradle (Standard) with 3 modes Skin / Air / Manual mode)

Resuscitation Unit with Fixed Baby Cradle (Standard) with 3 modes Skin / Air / Manual mode This is mobile Neonatal Resuscitation Unit mounted on wheels with fixed baby cradle & lower shelf along with facility of Oxygenation, Suction and Intubation Mechanical Specification Heater Box Consists of Ceramic Infra Red Heater 650 Watts Metallic Heater Box. The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards Halogen Examination Lamp (12 Volts, 50 Watts) To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Clear acrylic collapsible side panels . Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy. Acrylic tray and cushion mattress with head up/down facility. Acrylic X-ray tray with X-ray guide for positioning the cassette. The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf S.S. IV Stand. Oxygenation : Oxygen regulator with Hose pipe, Place to keep Cylinder, Chain to hold Oxygen Cylinder, Flow meter, Humidifier bottle, Silicone Patient Tubing, Manual Silicone Resuscitator 250ml with 00 & 01 size mask. Suction : Electrically operated low pressure Suction unit with 2 Autoclavable 500 ml suction jars, Regulator, Suction gauge and silicone tubing. Intubation : Laryngoscope with size 0 & 1 Straight Blades, Silicone Airways 000, 00 & 0

....


   

Resuscitation Unit with Fixed Baby Cradle (Standard) with 2 modes Skin / Manual mode

Product Code: NMCBS26042 - (Resuscitation Unit with Fixed Baby Cradle (Standard) with 2 modes Skin / Manual mode)

Resuscitation Unit with Fixed Baby Cradle (Standard) with 2 modes Skin / Manual mode This is mobile Neonatal Resuscitation Unit mounted on wheels with fixed baby cradle & lower shelf along with facility of Oxygenation, Suction and Intubation Mechanical Specification Heater Box Consists of Ceramic Infra Red Heater 650 Watts Metallic Heater Box. The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards Halogen Examination Lamp (12 Volts, 50 Watts) To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Clear acrylic collapsible side panels . Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy. Acrylic tray and cushion mattress with head up/down facility. Acrylic X-ray tray with X-ray guide for positioning the cassette. The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf S.S. IV Stand Oxygenation : Oxygen regulator with Hose pipe, Place to keep Cylinder, Chain to hold Oxygen Cylinder, Flow meter, Humidifier bottle, Silicone Patient Tubing, Manual Silicone Resuscitator 250ml with 00 & 01 size mask. Suction : Electrically operated low pressure Suction unit with 2 Autoclavable 500 ml suction jars, Regulator, Suction gauge and silicone tubing. Intubation : Laryngoscope with size 0 & 1 Straight Blades, Silicone Airways 000, 00 & 0

....


   

Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 3 modes Skin/Air/Manual

Product Code: NMCBS26046 - (Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 3 modes Skin/Air/Manual)

Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 3 modes Skin/Air/Manual Technical Specification Heater Box Heating Element : Ceramic Heater 650W with parabolic reflector, protected by metallic grid The source box can be swivelled to take X-ray Halogen Examination Lamp (12 Volts, 50 Watts) Provides accurate assessment of Infant colour and sufficient illumination during procedures Baby Tray with mattress Transparent acrylic, drop down and lockable side panels Baby Tray with mattress, along with head up/down facility and X-ray cassette holder Mattress density approx 21-25Kg/m3 and with removable, washable, waterproof cover Acrylic X-ray tray with X-ray guide for positioning the cassette The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf and plastic moulded 3 Storage Drawer Side tray for Monitor Pole for Syringe Pump / Infusion Pump S.S. IV Rod 4 swivel castors (100mm), 2 castors with brake Oxygenation : Integrated support for 10L oxygen Cylinder Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicone tubing for delivery of oxygen from humidifier bottle to patient Suction : Integrated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and Autoclavable Fluid Jar 500ml (2 nos.) and Silicone tubing Resuscitation : Silicone manual Resuscitator size Infant (250ml) with 00 and 01 size face masks. Laryngoscope - Penlight handle with size 0 and 1 straight blade Silicone Airways size 000, 00 and

....


   

Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 2 modes Skin/Manual mode

Product Code: NMCBS26047 - (Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 2 modes Skin/Manual mode)

Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 2 modes Skin/Manual mode Technical Specification Heater Box Heating Element : Ceramic Heater 650W with parabolic reflector, protected by metallic grid The source box can be swivelled to take X-ray Halogen Examination Lamp (12 Volts, 50 Watts) Provides accurate assessment of Infant colour and sufficient illumination during procedures Baby Tray with mattress Transparent acrylic, drop down and lockable side panels Baby Tray with mattress, along with head up/down facility and X-ray cassette holder Mattress density approx 21-25Kg/m3 and with removable, washable, waterproof cover Acrylic X-ray tray with X-ray guide for positioning the cassette The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf and plastic moulded 3 Storage Drawer Side tray for Monitor Pole for Syringe Pump / Infusion Pump S.S. IV Rod 4 swivel castors (100mm), 2 castors with brake Oxygenation : Integrated support for 10L oxygen Cylinder Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicone tubing for delivery of oxygen from humidifier bottle to patient Suction : Integrated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and Autoclavable Fluid Jar 500ml (2 nos.) and Silicone tubing Resuscitation : Silicone manual Resuscitator size Infant (250ml) with 00 and 01 size face masks. Laryngoscope - Penlight handle with size 0 and 1 straight blade Silicone Airways size 000, 00 and

....


   

Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 3 modes Skin/Air/Manual

Product Code: NMCBS26048 - (Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 3 modes Skin/Air/Manual)

Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 3 modes Skin/Air/Manual This is mobile Neonatal Resuscitation Unit mounted on wheels with fixed baby cradle & lower shelf along with facility of Oxygenation, Suction and Intubation Technical Specification Heater Box Heating Element Ceramic Heater 650W with parabolic reflector, protected by metallic grid The source box can be swivelled to take X-ray Halogen Examination Lamp (12 Volts, 50 Watts) Provides accurate assessment of Infant colour and sufficient illumination during procedures Baby Tray with mattress Transparent acrylic, drop down and lockable side panels Baby Tray with mattress, along with head up/down facility and X-ray cassette holder Mattress density approx 21-25Kg/m3 and with removable, washable, waterproof cover Acrylic X-ray tray with X-ray guide for positioning the cassette The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf Side tray for Monitor Pole for Syringe Pump / Infusion Pump S.S. IV Rod 4 swivel castors (100mm), 2 castors with brake Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicone tubing for delivery of oxygen from humidifier bottle to patient Suction : Integrated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and Autoclavable Fluid Jar 500ml (2 nos.) and Silicone tubing Resuscitation: Silicone manual Resuscitator size Infant (250ml) with 00 and 01 size face masks. Laryngoscope - Penlight handle with size 0 and 1 straight blade Silicone Airways size 000, 00 and 0....


   

Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 2 modes Skin/Manual mode

Product Code: NMCBS26049 - (Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 2 modes Skin/Manual mode)

Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 2 modes Skin/Manual mode This is mobile Neonatal Resuscitation Unit mounted on wheels with fixed baby cradle & lower shelf along with facility of Oxygenation, Suction and Intubation Technical Specification Heater Box Heating Element Ceramic Heater 650W with parabolic reflector, protected by metallic grid The source box can be swivelled to take X-ray Halogen Examination Lamp (12 Volts, 50 Watts) Provides accurate assessment of Infant colour and sufficient illumination during procedures Baby Tray with mattress Transparent acrylic, drop down and lockable side panels Baby Tray with mattress, along with head up/down facility and X-ray cassette holder Mattress density approx 21-25Kg/m3 and with removable, washable, waterproof cover Acrylic X-ray tray with X-ray guide for positioning the cassette The design aspects also allow ease of dismantling baby care area during cleaning or fumigation Essential Attachments Lower Shelf Side tray for Monitor Pole for Syringe Pump / Infusion Pump S.S. IV Rod 4 swivel castors (100mm), 2 castors with brake Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicone tubing for delivery of oxygen from humidifier bottle to patient Suction : Integrated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and Autoclavable Fluid Jar 500ml (2 nos.) and Silicone tubing Resuscitation: Silicone manual Resuscitator size Infant (250ml) with 00 and 01 size face masks. Laryngoscope - Penlight handle with size 0 and 1 straight blade Silicone Airways size 000, 00 and 0

....


   
< PREV    1 2    NEXT >
Hospital Supplies
Medical Equipment
Hospital Medical Supplies
Manufacturer Suppliers
Support