• HOME
  • ABOUT US
  • OUR PRODUCTS
  • Contact
Our Product
Puritan Bennett 7200 Series Ventilator

Puritan Bennett 7200 Series Ventilator

Product Code: NMCBS42004

Categories: Medical Ventilator

Tags: Puritan Bennett 7200 Series Ventilator

609

Download PDF Enquire Now
  • Description
  • Specification

Puritan Bennett 7200 Series Ventilator State-of-the-art gas delivery system Demonstrated track record of reliability Full-featured microprocessor-controlled ventilator with 7202 display screen Gas delivery features - Flow-by®, Pressure Support, Pressure Control Ventilation Patient monitoring features - Graphics 2.0, Respiratory Mechanics, Auto-PEEP Communications features - RS-232, Digital Communications Interface (DCI 2.0) Optional 7250® Metabolic Monitor Integrated safety systems Optional humidifier is available with this unit Indications For Usage: For use in providing pediatric and adult patients with ventilatory support in the hospital environment Specifications: Ventilator Dimensions: 41.9 cm H x 57.2 cm D x 55.9 cm W (16.5 in x 22.5 in x 22 in Ventilator Weight: 50.8 kg (112 lbs) Operator Selected Parameters Tidal Volume: .1 to 2.5 liters Respiratory Rate: .5 to 70 bpm Max Peak Inspiratory Flow: 120 Ipm during mandatory breather; 180 Ipm during spontaneous breathing. Sensitivity Inspiratory: .5 to 20 cmH2O bellow PEEP Oxygen Percentage: 21% to 100% Plateau: 0 to 2 seconds PEEP / CPAP: .1 to 2.5 liters, not to exceed twice tidal volume Sigh Rate and Frequency: 1 to 15 sighs per hour; 1 to 3 sighs per event Operator Selected Alarm Thresholds High Airway Pressure: 10 to 120 cmH2O Low Airway Pressure: 3 to 99 cmH2O PEEP / CPAP Pressure: 0 to 45 cmH2O Exhaled Tidal Volume: 0 to 2.5 liters Low Exhaled Minute Volume: 0 to 60 liters High Respiratory Rate: 0 to 70 bpm Sigh High Airway Pressure: 10 to 120 cmH2O, not to exceed twice high airway pressure Ventilatory Modes: Operator selectable. Continuous Manditory Ventilation (CMV). Synchronous Intermittent Mandatory Ventilation (SIMV). Continuous Positive airway Pressure (CPAP) Inspiratory Flow Waveforms: Square, descending ramp, or sine Alarm Control Functions: Alarm silence: silences alarm for 2 minutes. Alarm reset: resets ventilator to pre-alarm state of alert Parameters Display: Airway pressure; exhaled volume; type of breath: assist, spontaneous, sigh, and plateau; mean airway pressure; peak airway pressure; PEEP/CPAP pressure; plateau pressure; respiratory rate; I:E ratio; tidal volume; minute volume; and spontaneous minute volume

Puritan Bennett 7200 Series Ventilator Related Products

Other Highly Specialized Products for hospital lab and medical laboratory instruments such as Puritan Bennett 7200 Series Ventilator

Hospital Supplies
Medical Equipment
Hospital Medical Supplies
Manufacturer Suppliers
Support